Scope
What this checklist covers
The preparation ground these prompts walk through.
- Building the list of everything at a facility that will need attention
- Where the interval for each task is supposed to come from
- Splitting tasks between the operator and a specialist visit
- What a routine quietly assumes about access, isolation and equipment
- Fitting upkeep around the booking pattern and the turn of the season
- The written trail each completed or missed task is expected to leave
Audience
Who this checklist is for
- Owners preparing the upkeep side of a facility before it opens
- Operators who have inherited a facility with no schedule of any kind
- Committees dividing upkeep between volunteers and outside specialists
- Anyone preparing upkeep questions for installers at handover
Timing
When to use it
- Listing the parts of a facility that will need recurring attention
- Collecting intervals and methods from the people who installed each part
- Naming an individual against every recurring task on the site
- Working out what a routine assumes about access and equipment
- Preparing upkeep questions for installers, suppliers and specialists
Limits
When it is not sufficient
This is general planning preparation. These situations need a qualified professional, and often the relevant authority.
- Deciding how often anything at a facility should be serviced or checked
- Establishing what method, product or treatment suits a surface or a system
- Determining which statutory or governing-body checks apply to your facility
- Judging whether a defect is urgent, cosmetic or a reason to stop use
- Standing in for the aftercare instructions issued by installers
The checklist
Work through the sections
Tick the boxes on paper or on screen — nothing is stored, so print the page if you want to keep your marks.
1.Listing every part of the facility that will need attention
Schedules are usually built around the parts people can see from the entrance. Start by naming everything, including what is out of sight.
Walk the site and list every part that will need recurring attention, from the roof and gutters to the floors, doors, external areas and anything mechanical, before considering how often.
Deciding scope and frequency at the same time leads to a schedule shaped by what felt manageable rather than by what actually exists.
Note the parts that get forgotten because nobody looks at them, such as gutters, gullies, roof voids, extract vents and anything above head height.
These are the parts that fail expensively and silently, and they are absent from most schedules for no better reason than being out of eyeline.
List the systems that were installed rather than built, since each of these usually arrives with its own upkeep expectations from whoever fitted it.
What upkeep an installed system needs is described by the installer or a suitably qualified professional for that trade, against what was actually fitted here.
Record the soft items that wear rather than break, such as seating, mats, nets, curtains and door seals, which rarely reach a schedule at all.
Items that degrade gradually never trigger a call-out, so they are replaced only once they look shabby enough to embarrass somebody.
Include the grounds and approaches, such as paths, planting, boundary fences and the surface of any parking or turning area.
The approach is the first thing every user meets and the last thing any schedule covers, and its condition drives complaints out of all proportion to the effort involved.
Note anything on the site that belongs to a supply provider or a neighbouring owner, and mark it explicitly as outside your own schedule.
Where responsibility for a shared or provider-owned item ends is confirmed with that provider or owner, not assumed from where the item happens to sit.
2.Where each interval is supposed to come from
The single most useful discipline in a schedule is recording the source of every interval. Unsourced entries are the first to be dropped or doubled.
Ask each installer in writing what upkeep the part they fitted expects and how often, and record the answer in the words they gave it to you in.
Paraphrasing an installer loses precisely the qualifications that make the answer applicable to your facility rather than to facilities in general.
Note beside each interval where it came from, so a later reader can see whether it was given by an installer, taken from a maker or inherited from somebody's habit.
Schedules accumulate intervals nobody can account for, and an unsourced interval is the first thing to be quietly abandoned when effort is short.
Mark the tasks where you have no source at all, and treat those as open questions for a professional rather than gaps to fill in from general reading.
Intervals borrowed from another facility or from general reading may not apply here; each one is confirmed with the installer, the maker or the relevant authority.
Ask the local authority and the relevant governing body what they expect of a facility of this kind, and record what they tell you rather than deciding for yourself.
What checks are required at your facility is confirmed with the local authority and the relevant governing body, and requirements vary by location and by use.
Ask your insurer or broker whether any upkeep arrangement matters to them, and keep their answer with the schedule rather than in correspondence.
Anything touching cover or claims is a matter for your own insurer or broker, who are the only people able to say what applies to your facility.
Note where two sources say different things about the same part, and take the difference back to them rather than choosing between them yourself.
A disagreement between a maker and an installer usually means something specific about your installation, and asking surfaces it while both are still contactable.
3.Which tasks need somebody qualified and which do not
The line between what an operator can do and what needs a trade is drawn by the trade, not by the operator. Ask where it falls for each part.
Separate the tasks an operator can reasonably carry out from those needing somebody qualified, and ask each installer where that line falls for their part.
Operators consistently place the line too far towards themselves, because the tasks that look simple are rarely the ones that carry consequences.
Record which trade each specialist task belongs to, so the schedule names the kind of professional needed rather than describing the task alone.
A task with no trade attached becomes an internet search under pressure, which is the worst moment to be deciding who should be doing something.
Ask what would count as a competent person for each specialist task, and how you would establish that when engaging somebody.
Who is qualified to work on a given system is confirmed with the relevant trade body, the installer and the local authority, never assumed from a description.
Note tasks that look simple but sit close to something that is not, such as clearing a gutter beside an electrical run or cleaning around a heating unit.
Work near electrical, gas, heating or water installations stays with suitably qualified professionals, whatever the task itself appears to involve.
Write a person's name against each task the facility does for itself, and decide who covers that task when the named person is unavailable.
A task belonging to the committee belongs to nobody, and upkeep usually stops at a handover between people rather than through anybody neglecting it.
Agree how an outside specialist gets called in, who is permitted to make that call, and who looks at the result once the visit is over.
Visits that nobody reviews produce reports nobody reads, and the finding that mattered surfaces at the next visit instead.
4.What the schedule quietly assumes about access and equipment
Routines fail on practicalities far more often than on willingness. Test each task against what the site can actually supply.
Work out what each task assumes about reaching the part in question, and note anything that would need a ladder, a tower or an access platform.
Working at height and the equipment used for it are matters for suitably qualified professionals, with access arrangements agreed with them beforehand.
Record where isolation points, stopcocks and main switches are and who has shown them to you, without treating the knowledge as permission to use them.
What may be isolated, by whom and in what order is confirmed with the installer or a suitably qualified professional for that system.
List the equipment and consumables each task depends on, and check that the facility actually holds them before the schedule is agreed with anybody.
Writing this list before signing off a routine exposes the tasks that quietly depend on something nobody has ever bought.
Note which tasks need water or power at the point where the work happens, and whether either is genuinely available there.
A hose that does not reach or a socket at the wrong end of the building turns a short task into one that never happens.
Note whether a store exists for upkeep equipment at all, and whether it is the same store users open for their own gear.
Shared stores are where upkeep equipment migrates and disappears, and separating them is far easier to arrange before opening than afterwards.
Identify the tasks that cannot happen while the facility is occupied, and mark them clearly as needing a closed period.
These are the tasks that get postponed indefinitely, because no closure was ever planned for them and closing feels like a loss each time.
5.Weather, the turn of the season and the one-off tasks
Some tasks are driven by the calendar and some by what the sky has just done. Separate them, because they are managed differently.
Note which tasks are driven by weather rather than by any interval, such as clearing after a storm or looking at a roof after high wind.
Weather-driven tasks have no place in an interval-based schedule and simply disappear from it unless they are listed separately.
Record what the site does at the turn of the season, including leaf fall, frost, growth and anything that only appears at one point in the cycle.
Seasonal work is predictable a long way ahead, which makes it the easiest part of a schedule to get right and the most commonly rushed.
Write down the tasks that must happen before a period of closure and those that belong before reopening, and keep the two lists apart.
Closing tasks and reopening tasks get merged into one list and then performed at whichever end somebody remembered them.
Note anything that becomes impossible in cold or wet conditions, and ask the installer whether the task carries a weather limit at all.
Whether a treatment, coating or repair may be carried out in given conditions is confirmed with the supplier or installer, not judged from a forecast.
Record which parts of the site drain slowly or hold water after rain, and how that affects when work can be done in those areas.
Why water behaves as it does on a site is established by a qualified drainage professional rather than inferred from where puddles happen to sit.
6.Fitting upkeep around the pattern of bookings
A schedule that ignores how the facility is used will lose every collision with a booking. Set it against the real pattern from the start.
Set the schedule against the actual pattern of bookings, so tasks needing an empty facility land where the facility is genuinely empty.
Upkeep planned into nominally quiet periods that turn out to be busy is upkeep that will be deferred rather than rearranged.
Decide who is permitted to close a slot for upkeep and how users are told, and write that down before the first clash rather than during it.
The first collision between a booking and a task sets the precedent, and it is usually settled in favour of whoever asked loudest.
Note which tasks are noisy, dusty or block an entrance, and where those sit relative to neighbouring properties and other users of the site.
What restrictions apply to noise, permitted working times or access at your site is confirmed with the local authority and any conditions attached to the facility.
Record which upkeep can proceed alongside normal use and which cannot, taking that from the specialist rather than assuming it yourself.
Whether work can share a space with users is a judgement about the work, and the person doing it is the only one positioned to make it.
Note the quiet periods in the operating pattern and mark them as the natural home for anything disruptive or lengthy.
Naming these periods in advance prevents them being filled with bookings before the upkeep that needs them has been placed.
7.What each completed task leaves behind in writing
A schedule is a plan; the record is the evidence. Decide what a task produces before anybody carries one out.
Decide what a completed task leaves behind, whether that is a dated entry, a photograph, or a report from the specialist who attended.
Without deciding this in advance, completion is recorded as a tick, which tells whoever reads it later nothing at all.
Record who attended, what they actually did, and what they said still needs doing, rather than only that the visit took place.
The remark made on the way out is often the most valuable part of a visit and the part least likely to survive it.
Keep the reports issued by specialists in the same place as your own entries, so the history of the facility reads as a single sequence.
Split records force whoever investigates a problem to reconstruct a timeline from two half-stories, usually under time pressure.
Note how a skipped task is recorded, since a schedule showing only completions hides exactly the pattern you most need to see.
Recording what did not happen is more useful than recording what did, because it points at where the schedule is unrealistic.
Agree where the schedule and its records are kept and who else is able to open them, so neither depends on one person being reachable.
Upkeep records held privately are effectively lost, and their absence is discovered at the moment somebody needs the history.
Decide how the schedule and its records pass on if the operator, the committee or the ownership of the facility changes.
The next people responsible inherit the building automatically and the knowledge only if somebody arranged it.
8.Revisiting the schedule once real use has been seen
The first schedule is built on assumptions about how the facility will be used. Plan the moment when those assumptions get tested.
Plan to revisit the schedule once the facility has been in real use, since the first version rests entirely on guesses about how it would be used.
Actual use almost always differs from expected use, and the schedule is the last document anybody thinks to update when it does.
Note the tasks that keep slipping and treat that as information about the schedule rather than about the people carrying it out.
A routine nobody follows is better redesigned honestly than repeated in the hope that willingness will improve.
Record where wear or damage has actually appeared and whether the schedule anticipated that part at all.
Whether observed wear or damage affects continued use is established by the installer or a suitably qualified professional, not judged by the operator.
Ask regular users and visiting groups what they have noticed, since they see the facility in use in a way an operator rarely does.
Users register changes in how a place behaves long before anything is visible to somebody walking round with a list.
Note anything added to the facility since opening and check that it has been brought into the schedule rather than left to look after itself.
Additions arrive with attention and enthusiasm and are almost never entered into the routine that keeps everything else going.
Preparation
Documents and information to gather
Having these to hand usually makes the first conversation shorter and more useful.
- Aftercare and upkeep instructions issued by each installer at handover
- Maker instructions for anything mechanical, heated or powered on the site
- Any conditions attached to the facility by the local authority or the landowner
- Reports from any specialist who has already attended the site
- A plan or sketch showing where isolation points and shut-offs are located
- Whatever the relevant governing body publishes for facilities of this kind
Records
Decisions to record before work begins
Write these down in your own words, with the date, so everyone is working from the same version.
- Which tasks the facility carries out itself and which go to a specialist
- Who is named against each recurring task and who covers their absence
- How a slot is closed for upkeep and who is permitted to close it
- Where the schedule and its records are kept and who can open them
- What is recorded when a task is completed and when one is missed
- At what point the schedule is revisited against how the facility is really used
Professional review
Questions to discuss with qualified professionals
Bring these to the relevant qualified professional, supplier or authority. Requirements vary by project and location.
- What upkeep does the part you installed expect, and how often should it happen?
- Which of those tasks can an operator carry out and which need somebody qualified?
- What would count as a competent person for this task, and how would I establish that?
- What should never be done to this part, and what would tell me something is wrong?
- Can this work be done while the facility is in use, or does it need an empty building?
- Where are the isolation points for this system, and who is permitted to operate them?
- What conditions would make this task impossible or unwise to attempt?
- What do operators of facilities like this most often leave out of a schedule?
Blind spots
Commonly overlooked items
- Gutters, gullies and roof areas that nobody has been made responsible for
- Intervals copied from elsewhere with no source anybody can account for
- Tasks needing an empty facility scheduled into the busiest part of the season
- Soft items such as seating, mats and door seals that wear rather than fail
- Access equipment the schedule assumes and the facility does not hold
- Skipped tasks leaving no trace in a record that shows only completions
- Equipment added after opening and never brought into the routine
What this checklist does not do
- This checklist collects upkeep intervals and methods from the people responsible for each part; it never states how often anything at your facility should be done.
- Which checks are required at a facility, and by whom, varies by location and by use, and is confirmed with the local authority and the relevant governing body.
- Anything involving electrical, gas, heating, water or work at height stays with suitably qualified professionals, however routine the task appears on a list.
- Observations recorded by an operator are information to pass on, never a judgement that a facility or a part of it remains fit to be used.
More preparation
Related checklists
Inspiration
Related Ideas Library pages
Design directions to explore once the preparation is done.
- /ideas/commercial-sports-facilities/commercial-facility-phasing-direction →
- /ideas/commercial-sports-facilities/indoor-court-facility-direction →
- /ideas/commercial-sports-facilities/maintenance-and-storage-for-commercial-direction →
- /ideas/commercial-sports-facilities/accessibility-across-facility-direction →
Go deeper
Related Build Design Hub guides
Explanatory planning guidance behind the decisions on this page.
Facility Operations Readiness Checklists
Preparation checklists for running a facility day to day — information to assemble, routines to agree and records to set up before opening.